Can we trust the stopwatch?
To plan reception capacity, the team times calls with a stopwatch. Before using the times, Amara checks how much of the variation comes from the timing itself.
- 09:00Record 10 calls with Astrid (Data Analyst)
- 11:00Three people time each call twice
- 15:00Work out the gauge study with Augustin (Black Belt)
Situation 1 of 2
09:00 · Record 10 calls with Astrid (Data Analyst)How do you set up the check?
Situation 2 of 2
15:00 · Work out the gauge study with Augustin (Black Belt)How do you read it?
Linearity: is the stopwatch equally accurate for short and long calls?
Recordings of known length (2, 4, 6, 8 and 10 minutes, timed by the phone system) are each timed 3 times with the stopwatch. Bias = stopwatch time − true time.
| Recording | True length (min) | Stopwatch (min) | Bias (min) |
|---|---|---|---|
| T01 | 2 | 2.15 | 0.15 |
| T02 | 2 | 1.97 | -0.03 |
| T03 | 2 | 2.08 | 0.08 |
| T04 | 4 | 4.09 | 0.09 |
| T05 | 4 | 4.1 | 0.1 |
| T06 | 4 | 4.11 | 0.11 |
| T07 | 6 | 6.08 | 0.08 |
| T08 | 6 | 6.15 | 0.15 |
| T09 | 6 | 6.13 | 0.13 |
| T10 | 8 | 8.34 | 0.34 |
| T11 | 8 | 8.22 | 0.22 |
| T12 | 8 | 8.2 | 0.2 |
| T13 | 10 | 10.25 | 0.25 |
| T14 | 10 | 10.23 | 0.23 |
| T15 | 10 | 10.22 | 0.22 |
- Average bias
average of all 15 biases= +0.155 minutes (about 9 seconds) - Does bias change with size?
regress bias on the true length= bias = 0.009 + 0.0243 × length - Is the slope real?
p-value of the slope= 0.0005: yes - Bias at each end
at 2 minutes: 0.009 + 0.0243 × 2; at 10: 0.009 + 0.0243 × 10= 0.06 and 0.25 minutes
Try it yourself in a spreadsheet
| Bias | =C2-B2 |
| Slope and its p-value | =LINEST(D2:D16,B2:B16,TRUE,TRUE) |
| Average bias | =AVERAGE(D2:D16) |
If the slope had been 0.000 with an average bias of +0.15, what kind of problem would that be?
Show the answer
Pure bias: the same offset at every length. Correct it by subtracting 0.15 minutes; there's no linearity problem.
Gauge repeatability and reproducibility
Alma, Anouk and Arturo time 10 recorded calls twice each (minutes). The average and range method separates the stopwatch method's error from the real differences between calls.
| Call | Alma 1 | Alma 2 | Anouk 1 | Anouk 2 | Arturo 1 | Arturo 2 |
|---|---|---|---|---|---|---|
| Call 1 | 4.0 | 3.7 | 4.0 | 3.9 | 3.8 | 3.7 |
| Call 2 | 4.2 | 4.0 | 4.4 | 4.2 | 4.2 | 4.0 |
| Call 3 | 7.8 | 7.8 | 7.7 | 8.1 | 8.0 | 7.3 |
| Call 4 | 2.3 | 2.3 | 3.0 | 2.9 | 2.7 | 2.6 |
| Call 5 | 6.2 | 6.3 | 6.4 | 6.6 | 5.9 | 6.0 |
| Call 6 | 7.1 | 7.5 | 7.2 | 7.1 | 6.9 | 7.2 |
| Call 7 | 3.3 | 3.6 | 3.2 | 3.8 | 3.4 | 2.9 |
| Call 8 | 2.4 | 2.6 | 2.7 | 2.8 | 2.8 | 2.4 |
| Call 9 | 3.8 | 3.7 | 4.3 | 4.1 | 3.8 | 3.8 |
| Call 10 | 6.7 | 6.4 | 6.5 | 6.4 | 6.7 | 6.5 |
- Average range
for each person and call, the difference between their two times; average all 30= 0.22 minutes - Repeatability
average range × 0.8862 (for 2 trials)= 0.195 - Reproducibility
person averages differ by 4.965 − 4.730 = 0.235; √((0.235 × 0.5231)² − 0.195² ÷ (10 × 2))= 0.115 - Gauge error
√(0.195² + 0.115²)= 0.226 - Real variation between calls
range of call averages 5.167 × 0.3146= 1.625 - Gauge share
total = √(0.226² + 1.625²) = 1.641; gauge ÷ total = 0.226 ÷ 1.641= 13.8% - Distinct groups
1.41 × 1.625 ÷ 0.226= 10
Try it yourself in a spreadsheet
| Range for one person and call | =ABS(B2-C2) |
| Average range | =AVERAGE(H2:J11) (ranges in H to J) |
| Repeatability | =K12*0.8862 |
| Gauge share | =SQRT(EV^2+AV^2)/SQRT(EV^2+AV^2+PV^2) |
If the gauge error stayed at 0.226 but the calls varied much less (real variation 0.6), what would the gauge share be?
Show the answer
√(0.226² + 0.6²) = 0.641; 0.226 ÷ 0.641 = 35%. The same stopwatch would no longer be good enough: acceptability depends on what you're measuring.
Key concepts
The ideas behind today. Concept how the work is done, in our own words · Common practice widely used ways of working.
Precision: repeatability and reproducibility
- Repeatability: does one person get the same result twice? Reproducibility: do different people get the same result?
- Together they make the measurement error, compared with the total variation.
Where you will meet this: Gauge R&R · precision
Accuracy: bias, linearity and stability
- Bias: is the measurement right on average? Linearity: is the bias the same across the range? Stability: does it stay the same over time?
- Checked by measuring known standards.
Where you will meet this: Accuracy · bias · linearity · stability
Good enough for the purpose
- Gauge share under 10% is good, 10 to 30% may be acceptable depending on the decision, over 30% needs fixing. The method should also tell at least 5 groups of values apart.
Where you will meet this: % study variation · number of distinct categories
Explained in our own words. This helps you understand the concepts behind the certifications; it does not reproduce or replace any official guide. Sources
Day 19 complete
2 situations today.
- A gauge study measures the same items several times, by several people, to separate measurement error from real variation.
- Judge measurement error against the purpose: under 10% is good, 10 to 30% may be acceptable, over 30% needs fixing.