A chart that adds up how far each value is from the target, so small sustained shifts build up and show quickly.
Common practice 5 steps Used by Process Improvement Specialist
What it is
A CUSUM chart adds up the differences between each value and the target, minus an allowance k. Small sustained shifts build up until they cross the decision limit h.
When to use it
When small, lasting shifts matter and a standard chart would be slow to catch them.
Why it works
Standard charts are slow to catch small shifts. CUSUM catches them several times faster.
Do
Use it alongside a standard chart, which catches big sudden jumps faster.
Don't
Using it instead of, rather than alongside, a standard chart: it's slower to catch large sudden jumps.
After week 8 of roll-out, the locum covering two sessions starts cancelling some of them. The daily average wait creeps up by about half a day. Target 4.2 days, standard deviation 0.55.
Step by step
Individuals chartlimits 4.2 ± 3 × 0.55 = 2.55 to 5.85= no signal at all
The individuals chart never signals, because each day is still inside its limits. EWMA and CUSUM add up small differences over time and catch the drift within about 7 to 10 days of it starting.
What it led to
Aurelie (Practice Nurse Manager) finds the cancelled locum sessions and books a second locum. Add a CUSUM on the daily average wait to the control plan.
Do it in a spreadsheet
EWMA
=0.2*B3+0.8*C2 (C2 starts at 4.2)
EWMA limit
=4.2+3*0.55*SQRT(0.2/1.8*(1-0.8^(2*ROW()-2)))
CUSUM
=MAX(0,E2+B3-4.2-0.275)
Try it yourself: Why not just use a more sensitive individuals chart with limits at 2 standard deviations?
Tighter limits give many more false alarms on normal days. EWMA and CUSUM detect small sustained shifts without that cost.
In the roles
How a Process Improvement Specialist uses it
A half-day drift in waits: CUSUM signals on day 22; the I-MR chart never does.